MS2 Magnesense® II Differential Pressure Transmitter "DWYER"

Monitors Pressure, Air Velocity and Air Flow, BACnet/Modbus® Communications
The Series MS2 Magnesense® II Differential Pressure Transmitter combines stable piezo sensing technology with the additional features to reduce installation time and simplify ordering. Like the original Series MS, the second generation transmitter can be used as a linear pressure output or a linear velocity output with the square root extraction done in the transmitter. Additional parameters have been included on the MS2 to expand the square root capability to include flow measurements.
 

Specifications

Supported Baud Rates : 9600, 19200, 38400, 57600, 76800, 115200.

Data Size : 8.

Parity : None.

Stop Bits : 1.

Service : Air and non-combustible, compatible gases.

Wetted Materials : Consult factory.

Typical Accuracy : ±1% FS for 0.15 in w.c. (40 Pa), 0.25 in w.c. (50 Pa), 0.5 in w.c. (125 Pa), 2 in w.c. (500 Pa), 3 in w.c. (750 Pa), 5 in w.c. (1250 Pa), 10 in w.c. (2 kPa), 15 in w.c. (3 kPa), 25 in w.c. (5 kPa), 28 in w.c. (6.975 kPa); ±2% FS for 0.1 in w.c. (25 Pa), 1 in w.c. (250 Pa), and all bi-directional ranges.

Stability : ±1% / year FSO.

Temperature Limits : 0 to 150°F (-18 to 66°C).

Pressure Limits : 1 psi max., operation; 10 psi burst.

Power Requirements : 10 to 35 VDC (2-wire), 17 to 36 VDC or isolated 21.6 to 33 VAC (3-wire).

Output Signals : 4 to 20 mA (2-wire), 0 to 5 VDC, 0 to 10 VDC (3-wire).

Response Time :  Averaging 0 to 240 s, 2.5 Hz sample rate, 1.5 to 228 s for 95% step change.

Zero & Span Adjustments : Digital push buttons.

Loop Resistance : Current Output: 0 to 1250 Ω max;
Voltage Output : Min. load resistance 1 kΩ.

Current Consumption : 40 mA max.

Display (Optional) : 5 digit LCD.

Electrical Connections : 3-wire removable European style terminal block for 16 to 22 AWG.

Electrical Entry : 1/2" NPS thread; Accessory (A-151): Cable gland for 5 to 10 mm diameter cable.

Process Connection : 3/16" ID tubing (5 mm ID); Max. OD 9 mm.

Enclosure Rating : NEMA 4X (IP66).

Mounting Orientation : Any orientation.

 

Product Applications

- Duct Static Pressure in Commercial Buildings

- Filter Monitoring in Air Handler Units

- Building Pressure in Pharmaceutical-Semi-Conductor Clean Rooms

- Air Velocity/Flow in VAV Systems

 

  Download Catalog  
Catalog More information 
please contact us.
Tel : 02-911-4761-5 
Hotline : 095-365-8531
E-mail : pvn@pvn.co.th